FYI FORD - MustangSteve's Ford Mustang Forum
The Internet's Most Knowledgeable Classic Mustang Information
IF YOU HAVE A QUESTION ABOUT CLASSIC FORD MUSTANGS, YOU HAVE COME TO THE RIGHT PLACE!
MustangSteve has over 30 years of Mustang experience, having owned 30 of them and restored several others. With the help of other Mustangers, this site is dedicated to helping anyone wanting to restore or modify their Mustang.... THERE ARE NO DUMB QUESTIONS!!!!!
Visit MustangSteve's web site to view some of my work and find details for:
FYIFORD Contributors' PICTURES - Power Brake Retrofit Kits for 65-66 Stangs - Classic Mustang FAQ's by MustangSteve - How to wire in a Duraspark Ignition - Mustang Ride Height Pictures and Descriptions - Steel Bushings to fit Granada Spindles to Mustang Tie Rods - Visit my EBAY store MustangSteve Performance - How to Install Granada Disc Brakes MustangSteve's Disc Brake Swap Page - FYIFORD Acronyms for guide to all the acronyms used on this page - FYIFORD Important information and upcoming events

You are not logged in. Would you like to login or register?

7/02/2024 9:02 AM  #1


Third water pump fail

I really, really, really regret ever having installed that CVF Wraptor serpentine setup on my 69 Mustang. After having to remove EVERYTHING to install s new water pump, then having to re-shim the entire ststem to get pulleys to line up, the new water pump has mysteriously developed a grinding noise. It spun fine when I installed the fan.
You have to remove the fan and shroud in order to remove the belt to be able to see if everything spins properly.


Money you enjoy wasting is NOT wasted money... unless your wife finds out.
 

7/02/2024 12:17 PM  #2


Re: Third water pump fail

MS wrote:

I really, really, really regret ever having installed that CVF Wraptor serpentine setup on my 69 Mustang. After having to remove EVERYTHING to install s new water pump, then having to re-shim the entire ststem to get pulleys to line up, the new water pump has mysteriously developed a grinding noise. It spun fine when I installed the fan.
You have to remove the fan and shroud in order to remove the belt to be able to see if everything spins properly.

 
That is not what I want hear.  Maybe that’s why CVF told me a mechanical fan would void the warranty.  I bet they are having this issue a lot.  I did my research and thought I had picked a good system.  Ugh

 

7/02/2024 5:06 PM  #3


Re: Third water pump fail

Turns out it was not the pump internals. This time it was the crank pulley grinding into the water pump pulley!!! They ate so close together they actually rub each other.
I fixed the problem by running the engine with the car up on the lift, with the pulleys grinding against each other making a horrible noise.

I used my Dewalt angle grinder with a 40 grit flapper wheel to grind off most of the outer crank pulley flange until the noise went away. 

This is just a very sorry design. There should be at least 1/8” clearance between two rotating parts.

The worst part of the whole thing is all of it is held on with just four 5/16” bolts with nothing secured to the heads.  I will never again put money into something so ill-conceived.  Part of the problem was buying it based on pictures rather than seeing it in person first.

If you need good custom brackets, duplicate what RPM did on his car. Simple, sturdy and very effective.


Money you enjoy wasting is NOT wasted money... unless your wife finds out.
     Thread Starter
 

7/02/2024 5:31 PM  #4


Re: Third water pump fail

Steve, I had that same issue when I had the original 289 in my car. There was a lack of clearance between the CAA supplied cast iron pulley and the original w/p pulley. I ended up scrounging around and found a smaller diameter crank pulley.
I stayed with the “V” belts on the March billet pulley set  for the 331, they had no interference issues.
At the time I looked into a serpentine set up but would have needed two of those wider belts which would’ve stuck out too far froward causing fan to rad issues.


Good work ain't cheap, Cheap work ain't good!   Simple Man
 

7/02/2024 5:34 PM  #5


Re: Third water pump fail

MS wrote:

Turns out it was not the pump internals. This time it was the crank pulley grinding into the water pump pulley!!! They ate so close together they actually rub each other.
I fixed the problem by running the engine with the car up on the lift, with the pulleys grinding against each other making a horrible noise.

I sed my Dewalt angle grinder with a 40 grit flapper wheel to grind off most of the outer crank pulley flange until the noise went away. 

This is just a very sorry design. There should be at least 1/8” clearance between two rotating parts.

The worst part of the whole thing is all of it is held on with just four 5/16” bolts with nothing secured to the heads.  I will never again put money into something so ill-conceived.  Part of the problem was buying it based on pictures rather than seeing it in person first.

If you need good custom brackets, duplicate what RPM did on his car. Simple, sturdy and very effective.

 
Just out of curiosity perhaps RPM could refresh our memories with pict of his set up.
I’d like to admire his skills.🤩


Good work ain't cheap, Cheap work ain't good!   Simple Man
 

7/02/2024 6:26 PM  #6


Re: Third water pump fail

Just measured the distance between my pulleys and it is .067". That is not a lot of room between pulleys.

Last edited by KeithP (7/02/2024 6:26 PM)


1966, vert, 347 stroker, T5z, 4 wheel disc, pb, 3.70 LS 9", EPAS
 

7/02/2024 6:31 PM  #7


Re: Third water pump fail

KeithP wrote:

Just measured the distance between my pulleys and it is .067". That is not a lot of room between pulleys.

 
Not much but more than enough, can’t see any circumstance that will make them clash.


Good work ain't cheap, Cheap work ain't good!   Simple Man
 

7/02/2024 6:53 PM  #8


Re: Third water pump fail

Rudi wrote:

MS wrote:

Turns out it was not the pump internals. This time it was the crank pulley grinding into the water pump pulley!!! They ate so close together they actually rub each other.
I fixed the problem by running the engine with the car up on the lift, with the pulleys grinding against each other making a horrible noise.

I sed my Dewalt angle grinder with a 40 grit flapper wheel to grind off most of the outer crank pulley flange until the noise went away. 

This is just a very sorry design. There should be at least 1/8” clearance between two rotating parts.

The worst part of the whole thing is all of it is held on with just four 5/16” bolts with nothing secured to the heads.  I will never again put money into something so ill-conceived.  Part of the problem was buying it based on pictures rather than seeing it in person first.

If you need good custom brackets, duplicate what RPM did on his car. Simple, sturdy and very effective.

 
Just out of curiosity perhaps RPM could refresh our memories with pict of his set up.
I’d like to admire his skills.🤩

 
Sorry Rudi, but if you want to see other guy's cars up close and personal, ya gotta show up at the Bashes.

😁


Bob. 69 Mach 1, 393W, SMOD Toploader, Armstrong  steering, factory AC.
 

7/03/2024 12:46 AM  #9


Re: Third water pump fail

Rudi wrote:

MS wrote:

Turns out it was not the pump internals. This time it was the crank pulley grinding into the water pump pulley!!! They ate so close together they actually rub each other.
I fixed the problem by running the engine with the car up on the lift, with the pulleys grinding against each other making a horrible noise.

I sed my Dewalt angle grinder with a 40 grit flapper wheel to grind off most of the outer crank pulley flange until the noise went away. 

This is just a very sorry design. There should be at least 1/8” clearance between two rotating parts.

The worst part of the whole thing is all of it is held on with just four 5/16” bolts with nothing secured to the heads.  I will never again put money into something so ill-conceived.  Part of the problem was buying it based on pictures rather than seeing it in person first.

If you need good custom brackets, duplicate what RPM did on his car. Simple, sturdy and very effective.

 
Just out of curiosity perhaps RPM could refresh our memories with pict of his set up.
I’d like to admire his skills.🤩

 
Thank you Steve for the kind words.

My AC and alternator brackets ain't pretty Rudi, but they seem to work just fine. They are made from 1x¼ inch flat bar, and ¼ inch plate.














Bob. 69 Mach 1, 393W, SMOD Toploader, Armstrong  steering, factory AC.
 

7/03/2024 6:21 AM  #10


Re: Third water pump fail

Wow, I considered going to a sepentine belt system, now I'm glad I stayed with V-Belts. 


65 Fastback, 351W, 5-speed, 4 wheel discs, 9" rear,  R&C Front End.
 

7/03/2024 7:48 AM  #11


Re: Third water pump fail

RPM, aka Bearing Bob wrote:

Rudi wrote:

MS wrote:

Turns out it was not the pump internals. This time it was the crank pulley grinding into the water pump pulley!!! They ate so close together they actually rub each other.
I fixed the problem by running the engine with the car up on the lift, with the pulleys grinding against each other making a horrible noise.

I sed my Dewalt angle grinder with a 40 grit flapper wheel to grind off most of the outer crank pulley flange until the noise went away. 

This is just a very sorry design. There should be at least 1/8” clearance between two rotating parts.

The worst part of the whole thing is all of it is held on with just four 5/16” bolts with nothing secured to the heads.  I will never again put money into something so ill-conceived.  Part of the problem was buying it based on pictures rather than seeing it in person first.

If you need good custom brackets, duplicate what RPM did on his car. Simple, sturdy and very effective.

 
Just out of curiosity perhaps RPM could refresh our memories with pict of his set up.
I’d like to admire his skills.🤩

 
Thank you Steve for the kind words.

My AC and alternator brackets ain't pretty Rudi, but they seem to work just fine. They are made from 1x¼ inch flat bar, and ¼ inch plate.













 
Well done Bob. So basically simple yet totally efficient, unlike  a lot of over engineered, over priced products out there that don’t work.


Good work ain't cheap, Cheap work ain't good!   Simple Man
 

7/03/2024 10:40 AM  #12


Re: Third water pump fail

#10 is 5/8”, not 7/8”


Money you enjoy wasting is NOT wasted money... unless your wife finds out.
     Thread Starter
 

7/03/2024 11:12 AM  #13


Re: Third water pump fail

BobE wrote:

Wow, I considered going to a sepentine belt system, now I'm glad I stayed with V-Belts. 

 
I really like the V belt look much much more than serpentine belt.


Bob. 69 Mach 1, 393W, SMOD Toploader, Armstrong  steering, factory AC.
 

7/04/2024 4:43 AM  #14


Re: Third water pump fail

Well I really hope I don’t have these same issues with my CVF setup.

 

7/04/2024 9:13 PM  #15


Re: Third water pump fail

Rudi wrote:

KeithP wrote:

Just measured the distance between my pulleys and it is .067". That is not a lot of room between pulleys.

 
Not much but more than enough, can’t see any circumstance that will make them clash.

The circumstances that makes the pulleys hit is if a new water pump is installed and there is enough slop in the water pump mounting holes for it to slip down 0.068” before the bolts are tightened.

The pulleys did not interfere with the CVF supplied water pump or the Ford Racing water pump. Interference started when I installed the Made in USA Tuff Stuff water pump. There was significant interference.


Money you enjoy wasting is NOT wasted money... unless your wife finds out.
     Thread Starter
 

7/08/2024 7:08 PM  #16


Re: Third water pump fail

Perhaps something like this will work with that accessory drive.

 

7/08/2024 7:57 PM  #17


Re: Third water pump fail

Steve, have you thought about an electric water pump. You could probably get a good deal on an electric water pump and electric fan combo. I'm gonna go duck down behind this wall


Bob. 69 Mach 1, 393W, SMOD Toploader, Armstrong  steering, factory AC.
 

7/09/2024 6:11 PM  #18


Re: Third water pump fail

rpm wrote:

Steve, have you thought about an electric water pump. You could probably get a good deal on an electric water pump and electric fan combo. I'm gonna go duck down behind this wall

How would that look with some yellow spark
Plug wires??? We will never know, will we ?


Money you enjoy wasting is NOT wasted money... unless your wife finds out.
     Thread Starter
 

7/10/2024 8:11 AM  #19


Re: Third water pump fail

#8 and #10 in picture refers to the refrigerant line size.

3/4” and 7/8” in picture refers to the fitting thread size.

 

Board footera


REMEMBER!!! When posting a question about your Mustang or other Ford on this forum, BE SURE to tell us what it is, what year, engine, etc so we have enough information to go on.